mirror of
https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git/
synced 2025-04-19 20:58:31 +09:00
ASoC: ops: Apply platform_max after deciding control type
It doesn't really make sense for the type of a control to change based on the platform_max field. platform_max allows a specific system to limit values of a control for safety but it seems reasonable the control type should remain the same between different systems, even if it is restricted down to just two values. Move the application of platform_max to after control type determination in soc_info_volsw(). Signed-off-by: Charles Keepax <ckeepax@opensource.cirrus.com> Link: https://patch.msgid.link/20250319175123.3835849-4-ckeepax@opensource.cirrus.com Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
parent
94dfe71f0a
commit
502a668fad
@ -172,9 +172,6 @@ static int soc_info_volsw(struct snd_kcontrol *kcontrol,
|
||||
struct snd_ctl_elem_info *uinfo,
|
||||
struct soc_mixer_control *mc, int max)
|
||||
{
|
||||
if (mc->platform_max && mc->platform_max < max)
|
||||
max = mc->platform_max;
|
||||
|
||||
uinfo->type = SNDRV_CTL_ELEM_TYPE_INTEGER;
|
||||
|
||||
if (max == 1) {
|
||||
@ -185,6 +182,9 @@ static int soc_info_volsw(struct snd_kcontrol *kcontrol,
|
||||
uinfo->type = SNDRV_CTL_ELEM_TYPE_BOOLEAN;
|
||||
}
|
||||
|
||||
if (mc->platform_max && mc->platform_max < max)
|
||||
max = mc->platform_max;
|
||||
|
||||
uinfo->count = snd_soc_volsw_is_stereo(mc) ? 2 : 1;
|
||||
uinfo->value.integer.min = 0;
|
||||
uinfo->value.integer.max = max;
|
||||
|
Loading…
x
Reference in New Issue
Block a user