ASoC: ops: Apply platform_max after deciding control type

It doesn't really make sense for the type of a control to change based
on the platform_max field. platform_max allows a specific system to
limit values of a control for safety but it seems reasonable the
control type should remain the same between different systems, even
if it is restricted down to just two values. Move the application of
platform_max to after control type determination in soc_info_volsw().

Signed-off-by: Charles Keepax <ckeepax@opensource.cirrus.com>
Link: https://patch.msgid.link/20250319175123.3835849-4-ckeepax@opensource.cirrus.com
Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
Charles Keepax 2025-03-19 17:51:23 +00:00 committed by Mark Brown
parent 94dfe71f0a
commit 502a668fad
No known key found for this signature in database
GPG Key ID: 24D68B725D5487D0

View File

@ -172,9 +172,6 @@ static int soc_info_volsw(struct snd_kcontrol *kcontrol,
struct snd_ctl_elem_info *uinfo,
struct soc_mixer_control *mc, int max)
{
if (mc->platform_max && mc->platform_max < max)
max = mc->platform_max;
uinfo->type = SNDRV_CTL_ELEM_TYPE_INTEGER;
if (max == 1) {
@ -185,6 +182,9 @@ static int soc_info_volsw(struct snd_kcontrol *kcontrol,
uinfo->type = SNDRV_CTL_ELEM_TYPE_BOOLEAN;
}
if (mc->platform_max && mc->platform_max < max)
max = mc->platform_max;
uinfo->count = snd_soc_volsw_is_stereo(mc) ? 2 : 1;
uinfo->value.integer.min = 0;
uinfo->value.integer.max = max;